The Safety Department will periodically issue guidelines for subjects and situations which affect the safety and health of the campus community. These are not Ohio University policy. They represent best practices and proven methods to reduce incidents.

Cell Phone Use in University Vehicles

  • Cell phones should not be used to talk or text while driving.
  • Let your passenger handle all phone calls or text mes- sages.
  • Use message taking services or answering systems and call back later.
  • Let someone else drive if you anticipate making or re- ceiving calls or text messages.
  • Pull over and stop your vehicle in a safe location before using your cell phone.

Transporting Sick and/or Injured Employees

Extent of the Medical Concern (examples)

Minor

  • minor bleeding under control
  • no loss of consciousness (LOC)
  • able to walk
  • no open fractures
  • no vomiting or nausea
  • no chest, back or neck pains

Serious

  • unable to walk
  • open fractures
  • incoherent
  • chest, back, or neck pains
  • uncontrolled bleeding
  • recent loss of consciousness (LOC)
  • nausea or vomiting

Note: If any doubt, treat as serious

Mode of Transport

Minor

  • OU Vehicle with supervisor or other FA/CPR trained employee as driver
  • OU Police Department 3-1911 FA/CPR trained Officer and at Officers Discretion

Serious

  • Ambulance 911

Note: Should Not Transport by Private Owner Vehicles

Destination

Minor

  • UMA Express Care: 265 W. Union St., Monday thru Friday 9 AM to 6 PM, Saturday & Sunday 10 am to 6 pm
  • O’Bleness Emergency Room: 55 Hospital Drive, only when UMA-Express Care is closed

All Serious

  • O’Bleness Emergency Room

Pressure Vessels

Research pressure vessels are not currently regulated by any State of Ohio department, agency, local building department, or any other regulatory authority. However, we must assure that our students, faculty, staff, and contract personnel are not subject to injury or hazards associated with these pressure vessels. The following guidelines are provided:

Actions & Documentation

Design Parameters

These include the type, condition, and strength of the materials used, specifications for all components used, sources of materials and components, testing procedures and limits for each of the components and the finished vessel, life cycle analysis, safety factors used, and the sources of data.

Operational Parameters

Each Vessel must be labeled with applicable operational parameters such as the maximum allowable operating pressure, date placed into service, atmosphere(s) to be used, inspection and testing parameters, inspection frequency, and projected life. A document such as an Operations Manual and Log must be maintained and kept with each pressure vessel.

Inspections & Testing

Procedures and results of all initial testing conducted on the finished device and all components must be documented. Annual testing and any other periodic testing must be specified in the Operations Manual and Log. This document must list the procedures for testing, maintenance, and the results of these tests. All testing, activities, results, and records must be maintained for the life of each vessel.

Maintenance

Any maintenance, repairs, alterations, defects, failures, or other anomalies must be documented in the Operations Manual and Log.

Future Considerations

Equipment such as these vessels is normally intended for a specific project and period of use. They should not be used beyond their design life, or adapted to other experimental uses beyond their safe operational parameters. Internal labeling and record-keeping controls are extremely important to prevent use beyond the design life and safe operating parameters of each vessel.

Outdoor Lighting

The following operating guidelines apply to all new construction, renewal of building exteriors, and other outdoor improvements after 11/1/2010.

Area OneAverage LevelsMinimum Levels
High pedestrian activity2.5 FC (25 LUX).75 FC (8 LUX)
High volume parking lots2.5 FC (25 LUX).75 FC (8 LUX)
Parking garages2.5 FC (25 LUX).75 FC (8 LUX)

Examples:

  • Peden area, Baker Center, Ping Center, Memorial Auditorium, etc
  • Convocation Center lot, Peden lot, Baker Center garage, etc.
Area TwoAverage LevelsMinimum Level
Primary walkways 2 FC (20 LUX) .50 FC (5 LUX)
Primary streets2 FC (20 LUX).50 FC (5 LUX)

Examples:

  • Main Green Area, Jefferson Hill, Shivley Hall, South Green Front Four, etc.
  • All named roads
Area ThreeAverage LevelsMinimum Level
Secondary walkways1 FC (10 LUX).25 FC (3LUX)
Secondary streets parking lots1 FC (10 LUX).25 FC (3LUX)
Other outside use areas1 FC (10 LUX).25 FC (3LUX)

Examples:

  • East side of Bird Arena, behind Seigfred
  • Unnamed roads and alleys

Crosswalk Marking Guidelines

  • Crosswalks should be located at traffic-controlled intersections; however, they may be installed at other high pedestrian traffic areas as needed
  • Curb cuts should be made at all curb-to-crosswalk junctions to ensure handicapped access
  • All crosswalks will be marked in accordance with the Ohio Code as below. Also, additional markings or lighting may be used in high-hazard areas.

Crosswalk Lines

  • Materials: Thermoplastic
  • Colors: Alternating fluorescent yellow-green and white lines
  • Spacing: Lines should be 12” to 24” wide and spaced 12” to 60” apart. The marking design should avoid the wheel paths, and the spacing should not exceed 2.5 times the line width.