Monthly Energy Use & Energy Production for Greg Kremer's  1 kW wind and 0.96 kW solar RE system

(all values in KWH)

 

Cumulative Production for first 5 years (June 2004 through May 2010):

7480 KWH

Net sent to grid for first 5 years (June 2004 through May 2010):

3871 KWH
net positive

Approximate amount of coal that would have been burned to produce the same amount of electricity (assuming 2kWh / kg coal)

3740 kg, or
8228 pounds

Approximate amount of CO2 reduction

15,000 pounds

 

Approximate monthly averages for my production and use of electricity

 

Overall

Produced

110 kWh/month

Used

50 kWh/month

Sent to grid

60 kWh/month

 

 

Seasonal averages for my production and use
(as of December 2007, after 34 months of full production)

 

Spring

Summer

Fall

Winter

Produced (kWh/month)

135.5

106

95

111

Used (kWh/month)

41.2

49

44

55

Sent to grid (kWh/month)

94.3

57

51

56

 

2010

Date

Total

Produced

Cumulative

Production

Actual

Use

Sent to grid

Cumulative

sent to grid

Jan 10 to
May 10+

475

7480

341

134

3871

June 10 to Sep 10

408

7888

152

256

4127

Oct 10

Nov 10

Dec 10

+   gas line problems led to little to no gas service during this time,
increasing use of electricity

 

2009

Date

Total

Produced

Cumulative

Production

Actual

Use

Sent to grid

Cumulative

sent to grid

Jan 09

See combined numbers for Oct 08 – Jan 09 below

Feb 09

129

5916

53

76

3086

March 09

161

6077

40

121

3207

April 09

149

6226

30

119

3326

May 09

119

6345

39

80

3406

June 09

113

6458

40

73

3479

July 09

85

6543

42

43

3522

Aug 09

103

6646

56

47

3569

Sept 09

90

6736

36

54

3623

Oct 09

75

6811

42

33

3656

Nov 09

100

6911

25

75

3731

Dec 09

94

7005

88

6

3737

 

 

2008

Date

Total

Produced

Cumulative

Production

Actual

Use

Sent to grid

Cumulative

sent to grid

Jan 08

106

4528

58

48

2329

Feb to March 08

219*

4747

88*

131*

2460

April 08

118

4865

31

87

2547

May 08

126

4991

30

96

2643

June 08

122

5113

41

81

2724

July 08

100

5213

60

40

2764

Aug 08

108

5321

42

66

2830

Sept 08

100

5421

43

57

2887

Oct 08 to Jan 09 *

366

5787

243
(for 4 months)

123

3010

* Included an ice storm that resulted in power outage, and 4 days of no production from turbine
and solar panels due to being covered in ice.

 

2007

Date

AC In

AC Out

AEP

Meter

Total

Produced

Cumulative

Production

Actual

Use

Sent to grid

Cumulative

sent to grid

Jan 07

1223^

1800^

199704^

105^

3173

228^

-123^

1546

Feb 07

1305^

1828^

199678^

110^

3283

84^

26^

1572

March 07

1345

1920

199589

132

3415

43

89

1661

April 07

1378

2048

199464

161

3576

36

125

1786

May 07

1414

2147

199370

135

3711

40

94

1880

June 07

1450

2226

199294

115

3826

39

76

1956

July 07

1496

2292

199233

112+hp

3938

51+hp

61

2017

Aug 07

1539

2360

199178

111

4049

56

55

2072

Sept 07

 

 

199113

105

4154

40

65

2137

Oct 07

1612

2482

199066

90

4244

43

47

2184

Nov 07

1647

2543

199008

96

4340

38

58

2242

Dec 07

1688

2584

198969

82

4422

43

39

2281

 

2006

Date

AC In

AC Out

AEP

Meter

Total

Produced

Cumulative

Production

Actual

Use

Sent to grid

Cumulative

sent to grid

Jan 06

698

994

-350

128

1843.5

44

84

978

Feb 06

741

1084

-433

133

1976.5

49.5

83

1061

March 06

776

1178

-522

130

2106.5

41

89

1150

April 06

806

1306

199988**

157.5

2264

40.5

117

1267

May 06

837

1393

199911

116

2380

39

77

1344

June 06

 

 

 

101.5

2481.5

58

43.5

1387.5

July 06

916

1517

199824

101.5

2583

58

43.5

1431

Aug 06

959

1573

199779

99

2682

54

45

1476

Sept 06

995

1620

199741

83

2765

45

38

1514

Oct 06

1031

1688

199677

104

2869

40

64

1578

Nov 06

1073.5

1716.5

199651

71

2940

50

21

1599

Dec 06

1128

1790

199581

128

3068

58

70

1669

 

2005

Date

AC In

AC Out

AEP

Meter

Total

Produced

Cumulative

Production

Actual

Use

Sent to grid

Cumulative

sent to grid

Jan. 05

254.5

144

28988

47.5

549.5

48.7

-1.2

215.5

Feb. 05

298

181

28956

81

630.5

49

32

247.5

Prior to this date the battery charger was not temperature compensated, leading to a significant decrease in recorded production levels.  Therefore, the values for Feb 05 and earlier should not be included in predictions of potential system output.

Mar. 05

341

270

28870

132

762.5

46

86

333.5

Apr 05

373

379

28767.8

141

903.5

38.8

102.2

435.7

May 05

408.5

458.5

28699.5

115

1018.5

46.7

68.3

504

June 05

420

559

28612

112

1130.5

24.5

87.5

592.2

July 05

463.5

618.5

-25 *

103

1233.5

42.5

60.5

652.7

Aug 05

508.5

669.5

-63

96

1329.5

58

38

690.7

Sept 05

544

747.5

-133

113.5

1443

43.5

70

761

Oct 05

588

779

-155

75.5

1518.5

53.5

22

783

Nov 05

621

867

-235

121

1639.5

41

80

863

Dec 05

660

904

-266

76

1715.5

45

31

894

 

2004

Date

AC In

AC Out

AEP

Meter

Total

Produced

Cumulative

Production

Actual

Use

Sent to grid

Cumulative

sent to grid

 

 

 

29204.2

 

 

 

 

 

June 04

NA

NA

 

75 KWH

75 KWH

 

 

 

July 04

22

NA

29129.6

75

150

 

 

74.6

Aug. 04

60.5

18.5

29087.5

80

230

37.9

42.1

116.7

Sept 04

100.5

70

29047.5

91.5

321.5

51.5

40

156.7

Oct. 04

140

92

29033.1

61.5

383

47.1

14.4

171.1

Nov. 04

167

121

29007.7

56

439

30.6

25.4

196.5

Dec. 04

207

144

28987.5

63

502

42.8

20.2

216.7

·      The "AC In" meter records energy to the core loads (battery backup, refrigerator, furnace fan, and a few lights and outlets). 

·      The "AC Out" meter records energy to all other loads (very small amount) plus the amount sent to the grid. 

·      AEP meter values are my readings of the meter at the end of the month (*new digital meter installed,
**digital meter reset to 200000 in April to allow for backwards readings).

·      ^ : gas furnace failed and heat pump was used during a very cold week, leading to greatly increased use of electricity.  The heat pump apparently is not routed through the AC out meter, so it is only reflected in the AEP meter readings.

·      hp=heat pump.  It is sometimes used for cooling when I have visitors.  I try to indicate months that it is used since I do not believe the electricity it uses is directly metered by my system (it is included in the AEP meter).